Danfoss GD Gas Detection Units

Danfoss Authorized Distributor (China) Wenzhou Phonetoo is an authorized Danfoss distributor in China — listed in the official Danfoss dealer directory.

GD gas detection units monitor and warn of hazardous gas concentrations in industrial refrigeration plants, detecting commonly used refrigerants. These next-generation digital gas detectors connect to a central system — a gas detection controller or PLC — via analog signal or RS485 open Modbus communication, which converts the alarm signal into activation of alarm devices.

Wenzhou Phonetoo Electromechanical Co., Ltd. is an authorized Danfoss distributor in China. Contact us for availability, pricing and delivery time.

Key features

  • Digital, factory-configured and pre-calibrated — plug-and-play installation, no adjustment required
  • Factory default 2-step alarm setup ready for use; two individually configurable alarm ranges, password protected
  • Flexible connection: analog or RS485 open Modbus
  • Fieldbus wiring — connect and power up to 96 sensors, max. 900 m wire length per segment; expansion modules permit additional segments
  • Automatic self-diagnostics ensure correct communication and operation
  • Temperature-compensated sensors for higher accuracy and reduced risk of false alarms
  • Sensor seal cap prevents premature exposure during installation
  • LED status signals; Basic+ adds local buzzer & light for audio-visual alarms
  • On-board acknowledge button to reset alarms and verify no gas leaks are present

Series overview

SeriesDescription
GD Basic / Basic+Gas detection units for connection to a central system (gas detection controller or PLC)
GD Premium seriesGD, GD+, Duplex, Remote, Flex and Uptime variants — for standalone use or centralized monitoring, with on-board relays to activate alarm devices directly

The Premium series datasheet is currently available in Chinese — contact us and we will confirm the exact sensor type and alarm thresholds for your refrigerant.

Code numbers

Ordering codes for Danfoss GD gas detection units (Basic / Basic+ and Heavy Duty series). Confirm the exact type and code number in your RFQ and we will quote it.

SeriesModelRefrigerantSensorMeasuring rangeCode no.
GD BasicBasicAmmoniaElectrochemical0–100 ppm148H6000
GD BasicBasic+AmmoniaElectrochemical0–100 ppm148H6001
GD BasicBasicAmmoniaElectrochemical0–300 ppm148H6008
GD BasicBasic+AmmoniaElectrochemical0–300 ppm148H6009
GD BasicBasicAmmoniaElectrochemical0–1000 ppm148H6014
GD BasicBasic+AmmoniaElectrochemical0–1000 ppm148H6015
GD BasicBasicAmmoniaSemiconductor0–1000 ppm148H6023
GD BasicBasic+AmmoniaSemiconductor0–1000 ppm148H6024
GD BasicBasicAmmoniaSemiconductor0–10000 ppm148H6071
GD BasicBasic RemoteAmmoniaSemiconductor0–10000 ppm148H6073
GD BasicBasicAmmoniaPellistor0–140000 ppm148H6070
GD BasicBasicAmmoniaPellistor0–28000 ppm148H6080
GD BasicBasic RemoteAmmoniaPellistor0–28000 ppm148H6081
GD BasicBasicHFC (R32, R125, R143A, R404A, R407C, R410A, R434A, R448A, R452B, R507A)Semiconductor0–2000 ppm148H6045
GD BasicBasic+HFC (R32, R125, R143A, R404A, R407C, R410A, R434A, R448A, R452B, R507A)Semiconductor0–2000 ppm148H6046
GD BasicBasicCO2Infrared0–20000 ppm148H6072
GD Heavy DutyHeavy Duty (display)AmmoniaElectrochemical0–100 ppm148H6059
GD Heavy DutyHeavy Duty (display)AmmoniaElectrochemical0–300 ppm148H6060
GD Heavy DutyHeavy Duty (display)AmmoniaElectrochemical0–1000 ppm148H6022
GD Heavy DutyHeavy Duty (display)AmmoniaElectrochemical0–5000 ppm148H6031
GD Heavy DutyHeavy Duty (display)AmmoniaSemiconductor0–10000 ppm148H6035
GD Heavy DutyHeavy Duty (display)AmmoniaPellistor0–140000 ppm (0–100% LEL)148H6039
GD Heavy DutyHeavy Duty (no display)AmmoniaElectrochemical0–100 ppm148H6064
GD Heavy DutyHeavy Duty (no display)AmmoniaElectrochemical0–300 ppm148H6065
GD Heavy DutyHeavy Duty (no display)AmmoniaElectrochemical0–1000 ppm148H6066
GD Heavy DutyHeavy Duty (no display)AmmoniaElectrochemical0–5000 ppm148H6067
GD Heavy DutyHeavy Duty (no display)AmmoniaSemiconductor0–10000 ppm148H6068
GD Heavy DutyHeavy Duty (no display)AmmoniaPellistor0–140000 ppm (0–100% LEL)148H6069
GD Heavy DutyHeavy Duty (display)R290 / R1270 / R600APellistor0–5000 ppm148H6061
GD Heavy DutyHeavy Duty (display)R744 (CO2)Infrared0–50000 ppm (0–5% Vol)148H6075

Basic+ models include buzzer and light.

Spare parts and accessories

DescriptionCode no.
Replacement sensor – Ammonia EC 100148H6200
Replacement sensor – Ammonia EC 300148H6201
Replacement sensor – Ammonia EC 1000148H6202
Replacement sensor – Ammonia SC 1000148H6203
Replacement sensor – HFC R404A, R507 SC 2000148H6210
Replacement sensor – HFC R1234yf SC 2000148H6239
Replacement sensor – HFC R134a SC 2000148H6211
Replacement sensor – CO2 IR 20000148H6207
Replacement remote sensor – Ammonia P 28000148H6257
Replacement sensor – Ammonia P 28000148H6258
Replacement sensor – Heavy Duty Ammonia EC 100148H6240
Replacement sensor – Heavy Duty Ammonia EC 300148H6241
Replacement sensor – Heavy Duty Ammonia EC 1000148H6217
Replacement sensor – Heavy Duty Ammonia EC 5000148H6218
Replacement sensor – Heavy Duty Ammonia SC 10000148H6219
Replacement sensor – Heavy Duty Ammonia P LEL148H6220
Replacement sensor – Heavy Duty R290 / Propane P 5000148H6242
Replacement sensor – Heavy Duty CO2 IR 50000148H6255
Controller unit148H6231
Controller solution (controller + enclosure)148H6221
Controller solution uptime (UPS for controller)148H6237
Controller expansion module148H6222
Service tool148H6224
PC tool148H6235
Calibration adapter, Heavy Duty148H6233

Frequently asked questions

What is the Danfoss GD gas detection unit used for?

The GD is a gas detection unit for industrial refrigeration safety. It continuously monitors the air for refrigerant leaks and raises alarms before gas concentrations become hazardous.

Which gases can the GD detect?

It detects commonly used refrigerants, including ammonia (electrochemical sensor) — tell us which refrigerant you need to monitor and we will select the right sensor version. It can also detect Freon and carbon dioxide.

What is the difference between GD Basic and Basic+?

Both monitor and warn of hazardous gas concentrations; they differ in sensor and function options. Tell us the gas type and the area to be monitored and we will propose the correct version. The main difference between the two is that the Basic+ has a display while the GD Basic does not.

How do the alarms work?

The units come with a factory-default 2-step alarm setup: Alarm 1 is a pre-alarm when the gas level passes the first threshold, and Alarm 2 is the main alarm at the second threshold. Both thresholds are configurable via the integrated software.

How is the GD connected to the plant control system?

Each unit connects to a central Gas Detection Controller or a PLC by analog signal or RS485 open Modbus communication; the central system converts the alarm signal into activation of alarm devices such as sirens, beacons or ventilation.

Where should gas detectors be installed?

In machinery rooms, above or around potential leak points (valve stations, flanges, compressors), and in occupied cold storage areas — following local safety regulations for the refrigerant in use.

Does the sensor compensate for temperature changes?

Yes — the digital user interface with temperature compensation gives higher sensor accuracy and reduces false alarms from temperature swings in the plant room.

Is this a genuine Danfoss product? How long is delivery?

Yes. We are an authorized Danfoss industrial refrigeration distributor in China, listed in Danfoss China’s official authorized dealer directory. All units are brand-new, genuine stock with valid warranty. We ship from China; express delivery takes about 1–2 weeks to most destinations worldwide.